Heating load in Queensbury

A home in Queensbury has to be heated against a design temperature of −25.0 °C. That figure is measured, not modelled: it is the 1st percentile of daily minimum temperature over 16 years at Glens Falls/Floyd Bennett Memorial Airport, 4 km away.

Design temperature −25.0 °C
Heating degree days 3,128
Coldest month Jan
Coldest night on record −34.4 °C

How many kilowatts

Heating power needed at the design temperature, in kilowatts, for a detached house. Pick the row that matches the building.

Construction Detached Semi-detached Terraced Top-floor flat Mid-floor flat Ground-floor flat
Uninsulated, single glazed 29.0 kW 25.4 kW 22.6 kW 24.8 kW 12.1 kW 14.8 kW
Unfilled cavity, early double glazing 19.6 kW 16.9 kW 14.8 kW 14.4 kW 8.7 kW 10.9 kW
Insulated to 1980s standards 11.2 kW 10.1 kW 9.2 kW 8.6 kW 6.2 kW 7.9 kW
Modern, roughly 1995-2010 6.9 kW 6.3 kW 5.8 kW 5.6 kW 4.2 kW 5.1 kW
Current building regulations 5.3 kW 4.8 kW 4.5 kW 4.3 kW 3.3 kW 4.0 kW
Passive house 3.1 kW 2.8 kW 2.6 kW 2.5 kW 1.7 kW 2.2 kW

Where the heat goes

For a 120 m2 detached house of this construction, at the design temperature.

Element W Share
Walls 3,697 33%
Roof 1,080 10%
Ground floor 729 7%
Windows 2,106 19%
Thermal bridges 619 6%
Ventilation and draughts 2,984 27%
Heating load 11,214 11.2 kW

Calculate it for your own home

The climate half of this is measured. The building half is yours to supply.

Heating load

Monthly mean temperature

JanFebMarAprMayJunJulAugSepOctNovDec
°C −5.6 −4.6 0.4 7.8 14.5 18.7 21.6 20.2 16.1 9.7 3.4 −2.0