heatload

Heating load in Dover

A home in Dover has to be heated against a design temperature of −10.5 °C. That figure is measured, not modelled: it is the 1st percentile of daily minimum temperature over 25 years at Dover Afb Airport, 6 km away.

Design temperature −10.5 °C
Heating degree days 1,823
Coldest month Jan
Coldest night on record −18.9 °C
Coldest station in range −13.9 °C

How many kilowatts

Heating power needed at the design temperature, in kilowatts, for a detached house. Pick the row that matches the building.

Construction Detached Semi-detached Terraced Top-floor flat Mid-floor flat Ground-floor flat
Uninsulated, single glazed 19.7 kW 17.2 kW 15.3 kW 16.8 kW 8.2 kW 10.0 kW
Unfilled cavity, early double glazing 13.3 kW 11.5 kW 10.0 kW 9.7 kW 5.9 kW 7.4 kW
Insulated to 1980s standards 7.6 kW 6.8 kW 6.2 kW 5.9 kW 4.2 kW 5.4 kW
Modern, roughly 1995-2010 4.7 kW 4.3 kW 3.9 kW 3.8 kW 2.9 kW 3.4 kW
Current building regulations 3.6 kW 3.3 kW 3.0 kW 2.9 kW 2.2 kW 2.7 kW
Passive house 2.1 kW 1.9 kW 1.7 kW 1.7 kW 1.1 kW 1.5 kW

Where the heat goes

For a 120 m2 detached house of this construction, at the design temperature.

Element W Share
Walls 2,506 33%
Roof 732 10%
Ground floor 494 7%
Windows 1,427 19%
Thermal bridges 419 6%
Ventilation and draughts 2,022 27%
Heating load 7,601 7.6 kW

Calculate it for your own home

The climate half of this is measured. The building half is yours to supply.

Heating load

Monthly mean temperature

JanFebMarAprMayJunJulAugSepOctNovDec
°C 2.0 2.8 6.5 12.4 17.4 22.6 25.4 24.1 20.7 14.7 8.7 4.5

Where these numbers come from