Heating load in Adrian
A home in Adrian has to be heated against a design temperature of −20.0 °C. That figure is measured, not modelled: it is the 1st percentile of daily minimum temperature over 15 years at Adrian Lenawee County Arpt, 5 km away.
Design temperature
−20.0 °C
Heating degree days
2,808
Coldest month
Jan
Coldest night on record
−28.9 °C
Coldest station in range
−22.8 °C
How many kilowatts
Heating power needed at the design temperature, in kilowatts, for a detached house. Pick the row that matches the building.
| Construction | Detached | Semi-detached | Terraced | Top-floor flat | Mid-floor flat | Ground-floor flat |
|---|---|---|---|---|---|---|
| Uninsulated, single glazed | 25.8 kW | 22.6 kW | 20.1 kW | 22.0 kW | 10.7 kW | 13.1 kW |
| Unfilled cavity, early double glazing | 17.5 kW | 15.1 kW | 13.1 kW | 12.8 kW | 7.7 kW | 9.7 kW |
| Insulated to 1980s standards | 10.0 kW | 9.0 kW | 8.2 kW | 7.7 kW | 5.5 kW | 7.1 kW |
| Modern, roughly 1995-2010 | 6.1 kW | 5.6 kW | 5.2 kW | 4.9 kW | 3.7 kW | 4.5 kW |
| Current building regulations | 4.7 kW | 4.3 kW | 4.0 kW | 3.9 kW | 2.9 kW | 3.5 kW |
| Passive house | 2.8 kW | 2.5 kW | 2.3 kW | 2.2 kW | 1.5 kW | 2.0 kW |
Where the heat goes
For a 120 m2 detached house of this construction, at the design temperature.
| Element | W | Share |
|---|---|---|
| Walls | 3,286 | 33% |
| Roof | 960 | 10% |
| Ground floor | 648 | 7% |
| Windows | 1,872 | 19% |
| Thermal bridges | 550 | 6% |
| Ventilation and draughts | 2,652 | 27% |
| Heating load | 9,968 | 10.0 kW |
Calculate it for your own home
The climate half of this is measured. The building half is yours to supply.
Monthly mean temperature
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| °C | −3.7 | −3.4 | 2.5 | 8.9 | 15.8 | 20.7 | 22.9 | 21.4 | 17.7 | 11.1 | 4.3 | −0.8 |
Where these numbers come from
- Measured: the design temperature, the degree days and the monthly means. All of it from one station, Adrian Lenawee County Arpt, over 15 complete years.
- Assumed: everything about the building. The U-values are typical published figures for each construction era, not a survey of your house. Two houses of the same age and size can differ by a factor of two.
- No credit is taken for sunshine or for the heat given off by people and appliances. That is the EN 12831 convention, because the design condition is a still, dark night.
- This is space heating only. Domestic hot water is a separate load.
- This is a calculation, not a survey. Before spending money, have the building assessed.