Heating load in Spruce Grove
A home in Spruce Grove has to be heated against a design temperature of −35.5 °C. That figure is measured, not modelled: it is the 1st percentile of daily minimum temperature over 19 years at Edmonton Stony Plain Cs, 13 km away.
Design temperature
−35.5 °C
Heating degree days
5,466
Coldest month
Jan
Coldest night on record
−47.3 °C
How many kilowatts
Heating power needed at the design temperature, in kilowatts, for a detached house. Pick the row that matches the building.
| Construction | Detached | Semi-detached | Terraced | Top-floor flat | Mid-floor flat | Ground-floor flat |
|---|---|---|---|---|---|---|
| Uninsulated, single glazed | 35.8 kW | 31.4 kW | 27.8 kW | 30.5 kW | 14.9 kW | 18.2 kW |
| Unfilled cavity, early double glazing | 24.2 kW | 20.9 kW | 18.2 kW | 17.7 kW | 10.7 kW | 13.5 kW |
| Insulated to 1980s standards | 13.8 kW | 12.4 kW | 11.3 kW | 10.7 kW | 7.7 kW | 9.8 kW |
| Modern, roughly 1995-2010 | 8.5 kW | 7.8 kW | 7.2 kW | 6.9 kW | 5.2 kW | 6.3 kW |
| Current building regulations | 6.5 kW | 6.0 kW | 5.5 kW | 5.4 kW | 4.0 kW | 4.9 kW |
| Passive house | 3.8 kW | 3.5 kW | 3.2 kW | 3.0 kW | 2.0 kW | 2.7 kW |
Where the heat goes
For a 120 m2 detached house of this construction, at the design temperature.
| Element | W | Share |
|---|---|---|
| Walls | 4,559 | 33% |
| Roof | 1,332 | 10% |
| Ground floor | 899 | 7% |
| Windows | 2,597 | 19% |
| Thermal bridges | 763 | 6% |
| Ventilation and draughts | 3,680 | 27% |
| Heating load | 13,830 | 13.8 kW |
Calculate it for your own home
The climate half of this is measured. The building half is yours to supply.
Monthly mean temperature
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| °C | −12.0 | −10.1 | −4.6 | 3.0 | 10.2 | 14.2 | 16.5 | 15.8 | 10.6 | 3.8 | −4.9 | −11.3 |
Where these numbers come from
- Measured: the design temperature, the degree days and the monthly means. All of it from one station, Edmonton Stony Plain Cs, over 19 complete years.
- Assumed: everything about the building. The U-values are typical published figures for each construction era, not a survey of your house. Two houses of the same age and size can differ by a factor of two.
- No credit is taken for sunshine or for the heat given off by people and appliances. That is the EN 12831 convention, because the design condition is a still, dark night.
- This is space heating only. Domestic hot water is a separate load.
- This is a calculation, not a survey. Before spending money, have the building assessed.