Heating load in Sherwood Park

A home in Sherwood Park has to be heated against a design temperature of −33.7 °C. That figure is measured, not modelled: it is the 1st percentile of daily minimum temperature over 16 years at Oliver Agdm Alta, 15 km away.

Design temperature −33.7 °C
Heating degree days 4,670
Coldest month Dec
Coldest night on record −45.0 °C

How many kilowatts

Heating power needed at the design temperature, in kilowatts, for a detached house. Pick the row that matches the building.

Construction Detached Semi-detached Terraced Top-floor flat Mid-floor flat Ground-floor flat
Uninsulated, single glazed 34.6 kW 30.4 kW 26.9 kW 29.6 kW 14.4 kW 17.6 kW
Unfilled cavity, early double glazing 23.4 kW 20.2 kW 17.6 kW 17.2 kW 10.4 kW 13.0 kW
Insulated to 1980s standards 13.4 kW 12.0 kW 10.9 kW 10.3 kW 7.4 kW 9.5 kW
Modern, roughly 1995-2010 8.2 kW 7.5 kW 6.9 kW 6.6 kW 5.0 kW 6.1 kW
Current building regulations 6.3 kW 5.8 kW 5.4 kW 5.2 kW 3.9 kW 4.7 kW
Passive house 3.7 kW 3.4 kW 3.1 kW 2.9 kW 2.0 kW 2.6 kW

Where the heat goes

For a 120 m2 detached house of this construction, at the design temperature.

Element W Share
Walls 4,412 33%
Roof 1,289 10%
Ground floor 870 7%
Windows 2,513 19%
Thermal bridges 738 6%
Ventilation and draughts 3,560 27%
Heating load 13,382 13.4 kW

Calculate it for your own home

The climate half of this is measured. The building half is yours to supply.

Heating load

Monthly mean temperature

JanFebMarAprMayJunJulAugSepOctNovDec
°C −9.9 −9.8 −4.3 3.9 11.2 15.1 17.4 15.8 10.9 3.9 −3.9 −10.2

Where these numbers come from