Heating load in Prince Albert
A home in Prince Albert has to be heated against a design temperature of −37.0 °C. That figure is measured, not modelled: it is the 1st percentile of daily minimum temperature over 29 years at Prince Albert Glass Field, 7 km away.
Design temperature
−37.0 °C
Heating degree days
5,247
Coldest month
Jan
Coldest night on record
−46.1 °C
How many kilowatts
Heating power needed at the design temperature, in kilowatts, for a detached house. Pick the row that matches the building.
| Construction | Detached | Semi-detached | Terraced | Top-floor flat | Mid-floor flat | Ground-floor flat |
|---|---|---|---|---|---|---|
| Uninsulated, single glazed | 36.7 kW | 32.2 kW | 28.6 kW | 31.4 kW | 15.3 kW | 18.7 kW |
| Unfilled cavity, early double glazing | 24.9 kW | 21.4 kW | 18.7 kW | 18.2 kW | 11.0 kW | 13.8 kW |
| Insulated to 1980s standards | 14.2 kW | 12.8 kW | 11.6 kW | 10.9 kW | 7.9 kW | 10.0 kW |
| Modern, roughly 1995-2010 | 8.7 kW | 8.0 kW | 7.4 kW | 7.0 kW | 5.3 kW | 6.4 kW |
| Current building regulations | 6.7 kW | 6.1 kW | 5.7 kW | 5.5 kW | 4.1 kW | 5.0 kW |
| Passive house | 3.9 kW | 3.6 kW | 3.3 kW | 3.1 kW | 2.1 kW | 2.8 kW |
Where the heat goes
For a 120 m2 detached house of this construction, at the design temperature.
| Element | W | Share |
|---|---|---|
| Walls | 4,683 | 33% |
| Roof | 1,368 | 10% |
| Ground floor | 923 | 7% |
| Windows | 2,668 | 19% |
| Thermal bridges | 784 | 6% |
| Ventilation and draughts | 3,779 | 27% |
| Heating load | 14,204 | 14.2 kW |
Calculate it for your own home
The climate half of this is measured. The building half is yours to supply.
Monthly mean temperature
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| °C | −16.4 | −14.1 | −7.1 | 2.7 | 10.6 | 15.7 | 18.3 | 17.0 | 11.1 | 3.1 | −6.4 | −14.1 |
Where these numbers come from
- Measured: the design temperature, the degree days and the monthly means. All of it from one station, Prince Albert Glass Field, over 29 complete years.
- Assumed: everything about the building. The U-values are typical published figures for each construction era, not a survey of your house. Two houses of the same age and size can differ by a factor of two.
- No credit is taken for sunshine or for the heat given off by people and appliances. That is the EN 12831 convention, because the design condition is a still, dark night.
- This is space heating only. Domestic hot water is a separate load.
- This is a calculation, not a survey. Before spending money, have the building assessed.