Heating load in Cornwall

A home in Cornwall has to be heated against a design temperature of −27.2 °C. That figure is measured, not modelled: it is the 1st percentile of daily minimum temperature over 30 years at Massena Intl/Rchards Fd Ap, 13 km away.

Design temperature −27.2 °C
Heating degree days 3,513
Coldest month Jan
Coldest night on record −38.9 °C

How many kilowatts

Heating power needed at the design temperature, in kilowatts, for a detached house. Pick the row that matches the building.

Construction Detached Semi-detached Terraced Top-floor flat Mid-floor flat Ground-floor flat
Uninsulated, single glazed 30.4 kW 26.7 kW 23.7 kW 26.0 kW 12.7 kW 15.5 kW
Unfilled cavity, early double glazing 20.6 kW 17.8 kW 15.5 kW 15.1 kW 9.1 kW 11.5 kW
Insulated to 1980s standards 11.8 kW 10.6 kW 9.6 kW 9.1 kW 6.5 kW 8.3 kW
Modern, roughly 1995-2010 7.2 kW 6.6 kW 6.1 kW 5.8 kW 4.4 kW 5.3 kW
Current building regulations 5.5 kW 5.1 kW 4.7 kW 4.6 kW 3.4 kW 4.2 kW
Passive house 3.3 kW 3.0 kW 2.7 kW 2.6 kW 1.7 kW 2.3 kW

Where the heat goes

For a 120 m2 detached house of this construction, at the design temperature.

Element W Share
Walls 3,878 33%
Roof 1,133 10%
Ground floor 765 7%
Windows 2,209 19%
Thermal bridges 649 6%
Ventilation and draughts 3,129 27%
Heating load 11,762 11.8 kW

Calculate it for your own home

The climate half of this is measured. The building half is yours to supply.

Heating load

Monthly mean temperature

JanFebMarAprMayJunJulAugSepOctNovDec
°C −8.3 −7.1 −1.5 6.4 13.8 18.7 21.2 20.0 15.7 9.0 2.6 −4.0

Where these numbers come from